Solution Type  Problem Resolution Sure

Solution  1483222.1 :   SL24/48 - Amber LED On, Error Code A180  


Related Items
  • Sun StorageTek SL48 Tape Library
  •  
  • Sun StorageTek SL24 Tape Autoloader
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-6024657863>

Applies to:

Sun StorageTek SL48 Tape Library - Version All Versions and later
Sun StorageTek SL24 Tape Autoloader - Version All Versions and later
Information in this document applies to any platform.

Symptoms


Tape Library Amber LED is on. Error code: A180

Cause

A1 is the main code, and 80 is the sub code. Here are the explanations form service manual:

A1 Open Mailslot failed

80 Opening mailslot failed

 

Solution

• Retry the operation.
• Ensure that nothing is obstructing the opening of the mailslot.
• Remove the magazine and check for issues such as a tape label preventing the mailslot from opening.
• Verify the latest Firmware for SL48 has been installed. A lot of mailslot problems has been fixed.