Solution Type  Problem Resolution Sure

Solution  1479962.1 :   T10000A/B - Drive Will Hang When Pressing The Dump Button 1.48.x05 code  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

Sun StorageTek T10000A Tape Drive - Version Not Applicable and later
Sun StorageTek T10000B Tape Drive - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

 T10000A and T10000B drives will hang if you press the dump button on either the dmod itself or on the drive tray. This will only occur if the drive is running on 1.48.x05 microcode.

Cause

 A microcode code defect caused this problem.

Solution

A code change was written to correct the problem. It will be in the next release of T1000A/B code, forecast for 1.48.x07 or higher.

In the mean time use VOP or the library to force dumps on these drives types.

The T10000C drive is not affected by this problem .