Solution Type Problem Resolution Sure Solution 1479962.1 : T10000A/B - Drive Will Hang When Pressing The Dump Button 1.48.x05 code
In this Document
Applies to:Sun StorageTek T10000A Tape Drive - Version Not Applicable and laterSun StorageTek T10000B Tape Drive - Version Not Applicable and later Information in this document applies to any platform. SymptomsT10000A and T10000B drives will hang if you press the dump button on either the dmod itself or on the drive tray. This will only occur if the drive is running on 1.48.x05 microcode. CauseA microcode code defect caused this problem. SolutionA code change was written to correct the problem. It will be in the next release of T1000A/B code, forecast for 1.48.x07 or higher. In the mean time use VOP or the library to force dumps on these drives types. The T10000C drive is not affected by this problem . Attachments This solution has no attachment |
||||||||||||||||
|