![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1479666.1 : Intermitently new SPARC T3 & T4 system time(tod offset) is not saved when system is power downed
Applies to:SPARC T3-1 - Version Not Applicable to Not Applicable [Release N/A]SPARC T3-1B - Version Not Applicable to Not Applicable [Release N/A] SPARC T3-2 - Version Not Applicable to Not Applicable [Release N/A] SPARC T3-4 - Version Not Applicable to Not Applicable [Release N/A] SPARC T4-2 - Version Not Applicable to Not Applicable [Release N/A] SPARC SymptomsOn any of the SPARC T3 & T4 systems when we change the system time in Solaris ( date -u ) and is followed by a system shutdown, the new system time (tod offset) may not be reflected when the system is powered up. CauseN/A SolutionThe fix will be in both sysfw 8.1.6 (Available MOS in Sept. '2012 and supports for Oracle VM for SPARC LDoms 2.1): SPARC T3-1 -> Patch ID: 147315-07 SPARC T3-2 -> Patch ID: 147316-07 SPARC T3-4 -> Patch ID: 147317-07 SPARC T4-1 -> Patch ID: 147284-05 SPARC T4-1B -> Patch ID: 147287-05 SPARC T4-2 -> Patch ID: 147285-05 SPARC T4-4 -> Patch ID: 147286-06 and 8.2.1.b (Support for Oracle VM for SPARC LDoms 2.2): SPARC T3-1 -> Patch ID: 148816-02 SPARC T3-1B -> Patch ID: 48819-02 SPARC T3-2 -> Patch ID: 148817-02 SPARC T3-4 -> Patch ID: 148818-02 SPARC T4-1 -> Patch ID: 148822-03 SPARC T4-1B -> Patch ID: 148825-02 SPARC T4-2 -> Patch ID: 148823-03 SPARC T4-4 -> Patch ID: 148824-03
Current Workaround: eg: Attachments This solution has no attachment |
||||||||||||
|