Solution Type  Problem Resolution Sure

Solution  1479026.1 :   SL24 - Cannot Initialize Bar Code Reader  


Related Items
  • Sun StorageTek SL24 Tape Autoloader
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-6012905051>

Applies to:

Sun StorageTek SL24 Tape Autoloader - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

Error Can not initialize the barcode reader.

12.07.27 15:21:45.49 LIB/ERR   FF FF FF FF 00 20 20 20 20 20 20 20 20 20
  20 20 20 20 20 20 20 00 00 00 00 00 00 00
  00 > HE: cannot initialize bar code reader
12.07.27 15:16:28.73 LIB/ERR   FF FF FF FF 00 20 20 20 20 20 20 20 20 20
  20 20 20 20 20 20 20 00 00 00 00 00 00 00
  00 > HE: cannot initialize bar code reader
12.07.27 15:08:18.84 LIB/ERR   FF FF FF FF 00 20 20 20 20 20 20 20 20 20
  20 20 20 20 20 20 20 00 00 00 00 00 00 00
  00 > HE: cannot initialize bar code reader

Cause

Possible Causes
- Flexi cable connecting the barcode reader with the robot has damaged, disconnected.
- Barcode reader is damaged.
 
As the Cable gets disconnected or damaged or the barcode reader gets damaged, it fails to initialize the barcode reader and the error gets reported.

Solution

1. Reboot the library.
2. Inspect the flexi cable for any damages.
3. Check if customer can disconnect and reconnect the Flexi cable connecting the robot and barcode reader.
4. Replace the chassis.
 