![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1475876.1 : VSM posting FSC73E1 while staging microcode from VIP floppy.
While the VSM is on VIP, and CSE using the ECU option under vshell, the VSM posts FSC73E1 and fails to build the new SRL. In this Document
Applies to:Sun StorageTek VSM System - Version 4 to 4 [Release 4.0]IBM z/OS on System z SymptomsProcessing fact.cmd terminates with FSC 73E1. ChangesAll situations must apply for this KM to be true. VSM4 VSM4 is up on VIP disk. CSE is using vshell to communicate with the VSM. CSE is using the ECU command to stage a new code level on the VSM4. Processing fact.cmd terminates with FSC 73E1. CauseCSE is using downleverl version of VIP floppy SolutionCSE needs to create a new VIP floppy using image 4.2.3.2 NOTE: WinImage must be used to create the image since it must be a bootable floppy. Attachments This solution has no attachment |
||||||||||||||||||
|