Solution Type Problem Resolution Sure Solution 1474142.1 : SL150 - Incorrect Initial Configuration Does Not Allow a Connection to the Web GUI of the StorageTek SL150 Modular Tape Library
In this Document
Applies to:StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsCan not connect to the Web GUI of the SL150 library. CauseDuring the initial configuration using the Initial Config Wizard the IP address was set incorrectly. SolutionA factory reset will need to be done on the SL150 library so that the correct IP address can be set during the Initial Config Wizard.
To Do a Factory Reset on the SL150 Library: One person will need to stand at the front of the SL150 library and one person will need to stand at the rear of the SL150 library. The SL150 library will need to be in a powered up state. The person at the front of the library will need to push and hold the locate button on the front of the SL150 library and then the person at the rear of the library will need to push and hold the locate button on the rear of the SL150 library. The locate buttons will start to flash slowly, continue to hold in both of the locate bottons until the locate buttons start to flash quickly. Once the locate buttons flash at a fast rate both buttons can be released and the library will do a factory reset and will reinitialize. You now will have to go through the Initial Config Wizard in order to setup the SL150 library. Attachments This solution has no attachment |
||||||||||||||||
|