All fans are reported faulty in a Sun SPARC Enterprise T5240 Server
Related Items |
- Sun SPARC Enterprise T5240 Server
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5xx0
|
In this Document
Created from <SR 3-5921961221>
Applies to:
Sun SPARC Enterprise T5240 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
Customer reports a multiple fan failure and is probably suspecting of a faulty fan power board.
Changes
The issue is associated to Bug 6989852 that causes the system to display a strange message and also causes the 0 rpm FAN failure for all fans.
Cause
There are HW related warnings reported from explorer data collection such as the following:
##### Tx000/showfaults_-v #####
Last POST Run: Fri Jun 17 12:35:12 2011
Post Status: Passed all devices
ID Time FRU Class Fault
1 Jul 05 13:48:08 /SYS/FANBD0/FM1 SP detected fault: TACH at /SYS/FANBD0/FM1/F0 has reached low non-recoverable threshold.
2 Jul 05 13:48:02 /SYS/FANBD0/FM1 SP detected fault: TACH at /SYS/FANBD0/FM1/F1 has reached low non-recoverable threshold.
3 Jul 05 13:48:18 /SYS/FANBD0/FM0 SP detected fault: TACH at /SYS/FANBD0/FM0/F0 has reached low non-recoverable threshold.
4 Jul 05 13:48:13 /SYS/FANBD0/FM0 SP detected fault: TACH at /SYS/FANBD0/FM0/F1 has reached low non-recoverable threshold.
##### Tx000/showenvironment #####
/SYS/LOCATE /SYS/SERVICE /SYS/ACT
OFF ON ON
/SYS/PS_FAULT /SYS/TEMP_FAULT /SYS/FAN_FAULT
OFF OFF ON
(Note that ALL fans are reported faulty)
Sensor Status Speed Warn Low
/SYS/FANBD0/FM0/F0/TACH FAILED 0 4000 2400
/SYS/FANBD0/FM0/F1/TACH FAILED 0 4000 2400
/SYS/FANBD0/FM1/F0/TACH FAILED 0 4000 2400
/SYS/FANBD0/FM1/F1/TACH FAILED 0 4000 2400
Solution
Bug 6989852 is fixed in System Firmware 7.3.0 (patch 145676-01). Update to System Firmware 7.3.0 or higher.
Attachments