Asset ID: |
1-72-1473487.1 |
Update Date: | 2012-09-05 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1473487.1
:
Pillar Axiom: Cannot Boot, Slammer disabled (Ax600)
Related Items |
- Pillar Axiom 600 Storage System
|
Related Categories |
- PLA-Support>Sun Systems>DISK>Pillar Axiom>SN-DK: Ax600
|
In this Document
Created from <SR 3-5872455921>
Applies to:
Pillar Axiom 600 Storage System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Symptoms
Ax600 Axiom Cannot Boot, Slammer disable.
Changes
Issues happened after LUN creation.
Cause
It is not supported to combine 1MB ASM strip size with RAID mirroring (RAID10).
Solution
COD reset the system.
Please contact to Technical Solution Center.
References
@ <BUG:14238752> - AXIOM FAILS TO BOOT AFTER INVALID QOS COMBINATION (ASM + RAID10)
Attachments
This solution has no attachment