A false alert is detected in the IB Switch messages file for Power Supply Sensor. The issue is due to a bug

In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-5844578511>

Applies to:

Exadata Database Machine V2 - Version Not Applicable and later
Linux x86-64
Infiniband Switch detects a false alert for Power supply sensor
SUN DCS 36p version: 1.3.3-2

Symptoms

IB switch /var/log/message file will reports the below error

 Jun 16 21:10:2 dmorsw-ib1 envd[1553]: low I4 1.2V = 0.07 V
Jun 16 21:10:34 dmorsw-ib1 PEF: Sensor 'CHASSIS_STATUS' Type 0xC0 Data1 0xEntity 7 Instance 0
Jun 16 21:10:35 dmorsw-ib1 PEF: Sensor 'POWER_ATTN' Type 0xC0 Data1 0x0Entity 7 Instance 0
Jun 16 21:10:42 dmorsw-ib1 PEF: Sensor 'MB/V_I41.2V' Type 0x02 Data1 0x50 Entity 7 Instance 0
Jun 16 21:10:43 dmorsw-ib1 envd[1553]: Measured I4 1.2V = 1.22 V
Jun 16 21:10:44 dmorsw-ib1 PEF: Sensor 'CHASSIS_STATUS' Type 0xC0 Data1 0x00E
ntity 7 Instance 0
Jun 16 21:10:45 dmorsw-ib1 PEF: Sensor 'POWER_ATTN' Type 0xC0 Data1 0x00 Entity 7 Instance 0
Jun 16 21:10:52 dmorsw-ib1 PEF: Sensor 'MB/V_I41.2V' Type 0x02 Data1 0x51 Entity 7 Instance 0


checkpower, showunhealthy and env_test do not show any issue :

dmorsw-ib1# checkpower
PSU 0 present OK
PSU 1 present OK
All PSUs OK

dmorsw-ib1#  showunhealthy

OK - No unhealthy sensors


dmorsw-ib1# env_test
Environment test started:
Starting Environment Daemon test:
Environment daemon running
Environment Daemon test returned OK
Starting Voltage test:
Voltage ECB OK
Measured 3.3V Main = 3.27 V
Measured 3.3V Standby = 3.40 V
Measured 12V = 11.97 V
Measured 5V = 4.97 V
Measured VBAT = 3.18 V
Measured 2.5V = 2.50 V
Measured 1.8V = 1.78 V
Measured I4 1.2V = 1.22 V
Voltage test returned OK
Starting PSU test:
PSU 0 present OK
PSU 1 present OK
PSU test returned OK
Starting Temperature test:
Back temperature 32
Front temperature 32
SP temperature 46
Switch temperature 41, maxtemperature 48
Temperature test returned OK
Starting FAN test:
Fan 0 not present
Fan 1 running at rpm 11881
Fan 2 running at rpm 11772
Fan 3 running at rpm 12208
Fan 4 not present
FAN test returned OK
Starting Connector test:
Connector test returned OK
Starting Onboard ibdevice test:
Switch OK
All Internal ibdevices OK
Onboard ibdevice test returned OK
Environment test PASSED

Cause

 

 
    Customer Visible
The issue is described in the bug CR 6998891.

Solution

The alert can be ignored if it does not occurs frequently


The issue will be fixed in Infiniband Firmware release 2.0