Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1471581.1
Update Date:2012-07-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  1471581.1 :   SL500 - Legato Application Cell Confiuration Issue After Upgrading Library Firmware  


Related Items
  • Sun StorageTek SL500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-5745937702>

Applies to:

Sun StorageTek SL500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.
Checked for relevance on 16-July-2012.

Symptoms

Upgrade the firmware (all went ok) but the customer is now unable to use the library due to some licensing issues in Legato - it seems the library shows 124 slots while legato expects 64.

Changes

 Microcode upgrade from 1232 to latest version.

Cause

Cell licensing changed with the upgrade of microcode effecting Legato Application.

With lower level of firmware, the library would set cell capacity via the SILKs key process.  With microcode above 1300, cell capcity is set with partitioning.
 

Solution

Once firmware is upgraded in the library and a need for limited cell capacity is require, the Paritioning feature must be applied.  This is done via the Hardware Activation process.

SL500 - Where to Find Information on Partitioning (Doc ID 1019358.1)

SL500/SL3000/SL8500 - Oracle Software Delivery Cloud (E-Delivery) Hardware Activation Information (Doc ID 1299169.1)
 

References

@<NOTE:1305004.1> - How to Upgrade Firmware in SL500 Library:ATR:89:2
@<NOTE:1420313.1> - SL500 - Code Upgrade From 1395 to 1466 Can Corrupt RLC Controller Card

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.