Solution Type Problem Resolution Sure Solution 1471581.1 : SL500 - Legato Application Cell Confiuration Issue After Upgrading Library Firmware
In this Document
Created from <SR 3-5745937702> Applies to:Sun StorageTek SL500 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. Checked for relevance on 16-July-2012. SymptomsUpgrade the firmware (all went ok) but the customer is now unable to use the library due to some licensing issues in Legato - it seems the library shows 124 slots while legato expects 64. ChangesMicrocode upgrade from 1232 to latest version. CauseCell licensing changed with the upgrade of microcode effecting Legato Application. With lower level of firmware, the library would set cell capacity via the SILKs key process. With microcode above 1300, cell capcity is set with partitioning. SolutionOnce firmware is upgraded in the library and a need for limited cell capacity is require, the Paritioning feature must be applied. This is done via the Hardware Activation process. SL500 - Where to Find Information on Partitioning (Doc ID 1019358.1) SL500/SL3000/SL8500 - Oracle Software Delivery Cloud (E-Delivery) Hardware Activation Information (Doc ID 1299169.1) References@<NOTE:1305004.1> - How to Upgrade Firmware in SL500 Library:ATR:89:2@<NOTE:1420313.1> - SL500 - Code Upgrade From 1395 to 1466 Can Corrupt RLC Controller Card Attachments This solution has no attachment |
||||||||||||||||||||
|