Solution  1470536.1 :   Exadata: Removing power from rack, system failed to power on after power was restored  


Related Items
  • Exadata Database Machine V2
  •  
Related Categories
  • PLA-Support>Database Technology>Engineered Systems>Oracle Exadata>DB: Exadata_EST
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

Exadata Database Machine V2 - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

  • Removing power from entire rack
  • After restoring power to the rack, some systems remained power down
  • Affects all image versions including 11.2.3.1.1

 

Cause

 Unpublished <Bug 13578903>

Solution

 Workaround

 

  • Restart power of the servers throug the ILOM
    • ipmitool -H <ILOM address> -U root -P <password> chassis power on
    • Using the Web ILOM interface from Remote Control tab -. Remote Power Control and from the list of values, choose Select On