Solution Type Problem Resolution Sure Solution 1467535.1 : Messages shows kernel: ixgbe 0000:13:00.1: failed to load because an unsupported SFP+ module type was detected.
OEL 5.8 kernel - 2.6.32-300.21.1.el5uek #1 SMP In this Document
Created from <SR 3-5698627857> Applies to:Sun Fire X4170 M2 Server - Version Not Applicable and laterOracle Enterprise Linux 4.0 SymptomsX4170 M2 server has two dual-port 10GbE cards installed, yet an ifconfig -a only shows one interface from each card (plus the 4 on-board 1GbE interfaces). # ifconfig -a | grep HWaddr
Two interfaces from the dual-port 10gbe cards not listed:
# grep 'ixgbe_probe: failed to load' /var/log/messages
The physical interfaces that do not appear in ifconfig -a do not have the following line associated with them in an lspci -v output: Kernel driver in use: ixgbe The working interfaces do. ChangesN/A CauseFault with cables QSFP to 4x SFP+ Splitter Cable 530-4451 [R] X2125A-3M SolutionIf similar fault found , replace the Ethernet cable. Here it is QSFP to 4x SFP+ Splitter Cable 530-4451 [R] X2125A-3 With the replacement cables all interfaces are present and messges no longer shows any SFP errors. Attachments This solution has no attachment |
||||||||||||||||||
|