In this Document
Applies to:Sun StorageTek T10000B Tape Drive - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. SymptomsT1000B drive fails to come up afer it is power cycled with one of the following symptoms: 1) Boot Monitor 2) 6046 SNO 3) The drive does not IPL. (possibly with a solid red status LED) FSC6046 Error 6046 Will not initialize
The drive will fail no matter what library slot location it is installed in. ChangesThe drive was power cycled. CauseA chip has probably failed within the drive preventing it from running the bring up tests so that it will complete an IPL. SolutionThe drive must be replaced and sent back through the normal returns process. Attachments This solution has no attachment |
||||||||||||||||||
|