Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1460028.1
Update Date:2012-07-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  1460028.1 :   VTSS event log filliing up with FSC D0A0 and D123  


Related Items
  • Sun StorageTek VSM System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  


Trouble shooting FSC D0A0 and or D123

In this Document
Symptoms
Cause
Solution


Created from <SR 3-5720576221>

Applies to:

Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]
Information in this document applies to any platform.

Symptoms

VTSS event log filling up with FSC D0A0 and FSC D123

Cause

VTSS microcode D02.12.08.xx is incorrectly logging many FSC D0A0 D123 events.

The VTSS has IFF3 cards and active IP links to another VTSS and or VLE.
 

Solution

D02.14.32.00 microcode minimizes the number of these FSCs.

 


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback