![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1460028.1 : VTSS event log filliing up with FSC D0A0 and D123
Trouble shooting FSC D0A0 and or D123 In this Document
Created from <SR 3-5720576221> Applies to:Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]Information in this document applies to any platform. SymptomsVTSS event log filling up with FSC D0A0 and FSC D123 CauseVTSS microcode D02.12.08.xx is incorrectly logging many FSC D0A0 D123 events. The VTSS has IFF3 cards and active IP links to another VTSS and or VLE. SolutionD02.14.32.00 microcode minimizes the number of these FSCs.