Symptoms
FSC 1A4C error on a T10000 Drive
Changes
Possibly an online drive lost power, IPLed, or took a SNO which may cause the device to loose the assignment.
Cause
This is a cmd reject of a PSF (Perform Subsystem Function) order "Indentify Host Type". This error occurred because the PSF cmd was issued without the device first being assigned to the path. It is not a SNO.
Solution
Vary the device offline then back online to the host. If this an RTD then the host is the VTSS unit which is driven by VTCS commands.