Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1456194.1
Update Date:2012-05-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  1456194.1 :   Sun Fire [TM] V1280/E2900, Netra 1280/1290 ( LW8/Amazon/Everglades ): net1 Onboard Interface fails on boot net1 and test net1 of interface  


Related Items
  • Sun Fire E2900 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Netra 1280 Server
  •  
  • Sun Netra 1290 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: SF-x8x0/Ex900
  •  


net1 interface tests and boot net1 fail from OBP
No errors not present in OS - OS sees and allows use of net1 interface as normal

In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-5466513821>

Applies to:

Sun Fire E2900 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Netra 1280 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Netra 1290 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Fire V1280 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
The EIS recommendation is to set local-mac-address? true
This fix is counter to EIS recommendations.

Symptoms

The systems is showing errors against net1 Onboard Interface.

{0} ok test net1
Register tests: passed
Internal loopback test: Internal loopback packet RX failed
Exiting further tests
ERROR:  Selftest failed. Return code = -1

{0} ok boot net1
/ssm@0,0/pci@18,700000/network@3: 1000 Mbps full duplex link up
TL = 1, TT = 34. ERROR: Alignment Error
TSTATE= 0x1401 [ccr = 0x0, asi = 0x0, pstate = 0x14, cwp = 0x1]
TPC= 00000000f0038348
TNPC= 00000000f003834c
TICK= 8000002b32862ebc, TICKCMP = ffffffffffffffff
 

Attempting either of these commands using the full path (instead of the net1 alias) also fail the same way

Changes

 OBP perameters have been set to EIS recommendations

Cause

 local-mac-address? true

Solution

There has been cases where, even if OBP perameters have been set to EIS recommendations, before start shipping FRUs it worth try setting the OBP parameter as follows:

  ok setenv local-mac-address? false

and check if this fix the described issue.

 

See the Sun Fire V1280 / E2900 / N1290 EIS Checklist for reference


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback