![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1455772.1 : Sun Netra T5220 Server - Input power unavailable for PSU
SC Alert: ID 209813 daemon.alert Fault | critical: SP detected fault at time Thu Apr 19 12:48:46..2012. Input power unavailable for PSU at PS1 SC Alert: [ID 325448 daemon.alert] IPMI | critical: ID = d : 04/19/2012 : 12:48:26 : Voltage : /PS1/AC_POK : State Deasserted SC Alert: [ID 769395 daemon.alert] IPMI | critical: ID = e : 04/19/2012 : 12:48:27 : Power Supply : /PS1/FAIL : State Asserted Created from <SR 3-5665292312> Applies to:Sun Netra T5220 Server - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. SymptomsInput power is unavailable for PSU at PS1 as found in the messages file: Apr 19 06:09:30 bthcz3dns03 SC Alert: [ID 325448 daemon.alert] IPMI | critical: ID = d : 04/19/2012 : 12:48:26 : Voltage : /PS1/AC_POK : State Deasserted ChangesIf Power Circuit or Power Cord is interrupted from the source to the server, System Admins may generate Service Requests for investigation. CauseInput power problems are typically related to an interruption of a server's input power possibly due to a popped breaker or loose power cord. SolutionVerify that the PSU's breaker was not turned off and that the power cord was securely connected during the time of the problem. If the problem reoccurs after these items are checked, then PSU failure would be the most likely cause. Attachments This solution has no attachment |
||||||||||||
|