Symptoms
Cause
Solution


Created from <SR 2-8615486>

Applies to:

Pillar Axiom 600 Storage System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

Customer runs into the error below when attempting to extend any storage object on SSD bricks:
"Some of the values you entered are invalid. Please correct them and try again. MultiLevelCellSolidStateDrives"

Cause

This is an instance of Bug where certain upgrades from R3 to R4 resulted in SSD Bricks (and their volumes) are labeled into a group type incorrectly, and prevents any further use of those SSD Bricks.

Solution

  This is fixed in release above 040600, when upgrading from R3.