Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1450640.1
Update Date:2012-06-14
Keywords:

Solution Type  Problem Resolution Sure

Solution  1450640.1 :   Sun Storage 7000 Unified Storage System: Replication between two appliances fails with error message "xxxxx" after configuration has been changed  


Related Items
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun ZFS Storage 7320
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun ZFS Storage 7420
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>NAS>SN-DK: 7xxx NAS
  •  


Replication will fail if the IP address initially configured for use by replication is subsequently changed.

In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-5489566621>

Applies to:

Sun ZFS Storage 7120 - Version Not Applicable and later
Sun Storage 7410 Unified Storage System - Version Not Applicable and later
Sun Storage 7110 Unified Storage System - Version Not Applicable and later
Sun Storage 7310 Unified Storage System - Version Not Applicable and later
Sun ZFS Storage 7320 - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

Replication between two Sun Storage 7000 Unified Storage Systems fails with error messages after configuration has been changed or a factory reset was executed on target side.

Common messages are:

Source:

  • broken pipe

Target:

  • incorrect source system

Cause

Replication creates a trusted relationship based on a token, which is created during setup of the replication. One major part which goes into the replication 'association' is the IP address of source and destination, in other words the Sun Storage 7000 unified storage expects the exchange of data and the ackonwledgements to happen through the same network interfaces using the same IP addresses specified during the configuration phase.

Important considerations:

  • Routing must be correct before starting the configuration or you might lock yourself into the wrong interface, host routes are recommended.
  • Replication actions are based on IP address
  • You CANNOT change IP address after the configuration has been set
  • Both nodes in a cluster need to replicate to different IP address on target
  • Replication source and destination must be same major code
  • Replication destination must be the same or newer minor code release
  • There is currently no way to move packages between storage pools or change the IP address associated with an action.


If the IP addresses for the replication source & target systems has been changed. The target system may show an 'incorrect' source system.

Solution

To recover from this situation it is neccessary to remove the replication setup and all related actions, packages and snapshots. Then a new replication setup needs to be created with the correct and final settings.

A good source of information is Sun Storage 7000 Unified Storage System Administrators Guide in section Replication

References

<NOTE:1398023.1> - Sun Storage 7000 Unified Storage System: Unable to start a replication to a remote appliance
<NOTE:1397959.1> - Sun Storage 7000 Unified Storage System: How to Troubleshoot Replication Issues

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback