![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1437963.1 : T10000C - List of Changes / Fixes in 1.53.315 Code
In this Document
Applies to:StorageTek T10000C Tape Drive - Version: Not ApplicableInformation in this document applies to any platform. SymptomsSAM QFS: T10KC intermittently returns invalid read position data. Previously in Special build RA53.311.FSC32E0 Fix 32E0 intermittent timing problems during many space file reads. Previously in Special build RB53.311. FSC3671 No tape volume displayed in IEA486E message after MIR update fails on dismount of tape. Allow T10KC to operate on IBM I-series Power 7 processor. (AS400) FSC3943 FSCDC57 3493, DC57 Retries after positioning to EOD. Previously in Special build RC53.311. FSC0934 Fix for 0934 SNO. Previously in Special build RD53.311. FSCA724, A724 Customer request to be able to use MakeDataTape utility upon tapes in both ALP mode and Standard modes. FSC0930 Fix for 0930 SNO. This bug has only been seen & reported in a VSM/ALP configuration. There is a very low potential for this to occur in non-ALP configurations. FSC3697 Fix for 3697 SNO. This bug is isolated to ALP configurations only. CauseIssues within microcode that required resolution.SolutionUpgrade firmware 1.53.315 to address issues described above.This release of code fixes issues identified with prior releases. How to Upgrade T10000 Tape Drive Firmware/Microcode:ATR:741:2 (Doc ID 1347640.1) Attachments This solution has no attachment |
||||||||||||
|