Solution Type  Problem Resolution Sure

Solution  1436003.1 :   T5240 panic panic string: BAD TRAP: type=31 rp=2a1062395b0 addr=0 mmu_fsr=0 occurred in module "unix" due to a NULL pointer dereference  


Related Items
  • Sun SPARC Enterprise T5240 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5xx0
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
  •  




In this Document
  Symptoms
  Cause
  Solution
  References


Applies to:

Sun SPARC Enterprise T5240 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Information in this document applies to any platform.

Symptoms

System is stuck at a reboot loop.

System panic's

panic string: BAD TRAP: type=31 rp=2a1062395b0 addr=0 mmu_fsr=0 occurred in module "unix" due to a NULL pointer dereference

Cause

Bug in CR# 6942564

Solution

The recommendation is to update Solaris 10 kernel patch 144488-03 or newer .