![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1436003.1 : T5240 panic panic string: BAD TRAP: type=31 rp=2a1062395b0 addr=0 mmu_fsr=0 occurred in module "unix" due to a NULL pointer dereference
In this Document
Applies to:Sun SPARC Enterprise T5240 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/AInformation in this document applies to any platform. SymptomsSystem is stuck at a reboot loop.System panic's panic string: BAD TRAP: type=31 rp=2a1062395b0 addr=0 mmu_fsr=0 occurred in module "unix" due to a NULL pointer dereference CauseBug in CR# 6942564SolutionThe recommendation is to update Solaris 10 kernel patch 144488-03 or newer .References<BUG:6942564> - BAD TRAP OCCURS WHEN HALTING A ZONE STUCK IN 'DOWN' STATEAttachments This solution has no attachment |
||||||||||||
|