Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1421441.1
Update Date:2012-06-15
Keywords:

Solution Type  Problem Resolution Sure

Solution  1421441.1 :   Two Infiniband Switches In an Exalogic Rack are showing Different Outputs for the Ibswitch Command  


Related Items
  • Infiniband Cable
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>x64>Engineered Systems HW>SN-x64: EXALOGIC
  •  
  • PLA-Support>Database Technology>Engineered Systems>Oracle Exalogic>MW: Exalogic Core
  •  




Created from <SR 3-5364045521>

Applies to:

Infiniband Cable - Version Not Applicable to Not Applicable [Release N/A]
Oracle Exalogic Elastic Cloud X2-2 Hardware - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

Running the 'ibswitches' command on 2 infiniband switches in an Exalogic rack results in different output for each switch.

Cause

A bad port connection between an infiniband switch and the Exalogic rack's Cisco switch is the cause.

Physically examining the infiniband switches reveals that the link light for a port on one of the infiniband switches is off.

Solution

If the 'ibswitches' command is run on multiple infiniband switches and the outputs of the 'ibswitches' commands show inconsistencies:

1) Examine the LED's associated with the ports on the infiniband switches; and
2) If an LED for a port on one of the infiniband switches is not lit, reconnect the cable for the connection between the non-lit port and the Cisco switch;
3) After observing that the non-lit LED is now lit, re-run the 'ibswitches' command on the infiniband switches to verify that the outputs are no longer inconsistent.


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.