In this Document Created from <SR 3-5363549151>
Applies to:Sun StorageTek L180 Tape Library - Version: Not ApplicableSun StorageTek L700e Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L1400 Tape Library - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform. SymptomsFSC30B9FSC 30B9 Service required light flashing red Cause30b9ERR_SRV_EM_FAN_1_FAILURE, A fan failure was detected on electronics module fan #1. FRU: LOCATION: CONFIDENCE %: FAN E/M LSM 90 MPC LCU 9 Logical Error S/W 1 1. Service Required indicator is steadily red when human intervention is required and flashes if a fan is defective. SolutionFan is diagnosed as being bad and requires replacement by service representativeReplace the defective electronics module fan. Refer to following knowledge entry for instructions on fan replacement L180/L700/L1400 - How to replace an electronics module fan in a library:ATR:1421338.1:2 (Doc ID 1421338.1) References<NOTE:1015288.1> - L180/L700/L1400 - Troubleshooting Process to Resolve Library IssuesAttachments This solution has no attachment |
||||||||||||
|