Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1395656.1
Update Date:2012-02-29
Keywords:

Solution Type  Problem Resolution Sure

Solution  1395656.1 :   nxge Interface will not plumb  


Related Items
  • Sun SPARC Enterprise T2000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Usx/Blade/Netra>SN-SPARC: USx
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>CMT Servers
  •  




In this Document
  Symptoms
  Cause
  Solution


Created from <SR 3-4737029832>

Applies to:

Sun SPARC Enterprise T2000 Server - Version: Not Applicable and later   [Release: N/A and later ]
Information in this document applies to any platform.

Symptoms


The Customer has recently installed 501-7601 nic and it will not plumb

systema# ifconfig nxge0 plumb
ifconfig: cannot open link "nxge0": No such device or address


The following messages are output:

dmesg.out:Aug 24 16:59:37 system nxge: [ID 752849 kern.warning] WARNING: nxge0
: EEPROM version [QGC 1G Ethernet Adapter FCode 2.8 06/12/13] invalid...please update
dmesg.out:Aug 24 16:59:37 system nxge: [ID 752849 kern.warning] WARNING: nxge0
: get_hw create failed

Cause


NIC has old firmware 2.8 Fcode with known defects


Solution


Replace the current nxge NIC with an upgraded NIC (upgraded Fcode).

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.