![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1395656.1 : nxge Interface will not plumb
In this Document Created from <SR 3-4737029832>
Applies to:Sun SPARC Enterprise T2000 Server - Version: Not ApplicableInformation in this document applies to any platform. SymptomsThe Customer has recently installed 501-7601 nic and it will not plumb systema# ifconfig nxge0 plumb ifconfig: cannot open link "nxge0": No such device or address The following messages are output: dmesg.out:Aug 24 16:59:37 system nxge: [ID 752849 kern.warning] WARNING: nxge0 : EEPROM version [QGC 1G Ethernet Adapter FCode 2.8 06/12/13] invalid...please update dmesg.out:Aug 24 16:59:37 system nxge: [ID 752849 kern.warning] WARNING: nxge0 : get_hw create failed CauseNIC has old firmware 2.8 Fcode with known defects SolutionReplace the current nxge NIC with an upgraded NIC (upgraded Fcode). Attachments This solution has no attachment |
||||||||||||
|