![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1390005.1 : Sun Netra X4270 : Unable to poweron
Server Unable to power . "-->start /SYS" from ILOM give error "start: Not enough available power". Created from <SR 3-5028929617>
Applies to:Sun Netra X4270 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/AInformation in this document applies to any platform. SymptomsSun Netra X4270 server unable to power on.The command "start /SYS" when run from the ILOM CLI may give the following error: "start: Not enough available power" -> start /SYS ChangesThis may infrequently occur when there is a sudden power outage.CauseIn case of power loss, the fault management logic in the service processor of the server marks both PS0 and PS1 as faulty as per the below example:->show faulty SolutionClear the fault conditions registered for each power supply using logging into the service processor and issuing the following commands:
Attachments This solution has no attachment |
||||||||||||
|