Solution Type Problem Resolution Sure Solution 1381058.1 : Sun Storage 7000 Unified Storage System: Last Message On The Screen Is "Loading Grub Stage 2 ......"
In this Document
Created from <SR 3-4981090373> Applies to:Sun Storage 7110 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A]Sun Storage 7210 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 7310 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 7410 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun ZFS Storage 7320 - Version Not Applicable to Not Applicable [Release N/A] 7000 Appliance OS (Fishworks) Symptoms
"Loading GRUB stage 2 ......." CauseThe reason for the observed behavior is most likely a monitor directly connected to the appliance head of the system instead of using the system console on service processor. Loading GRUB stage 2....... SolutionThe Sun Storage 7000 Unified Storage System is designed to redirect the system console output to the ILOM console. To verify that the system is booting and can be reached via network it is best to wait a couple of minutes and see if the system responds to a ping. If the system responds it has booted and you are fine.
See the install poster for your system model or verify the installation or maintenance documentation.
https://wikis.sun.com/display/FishWorks/Documentation Attachments This solution has no attachment |
||||||||||||||||
|