Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1371346.1
Update Date:2011-10-28
Keywords:

Solution Type  Problem Resolution Sure

Solution  1371346.1 :   T10000A - Cannot Set FICON Emulation in a 4 GB Drive  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
  Symptoms
  Changes
  Cause
  Solution


Applies to:

Sun StorageTek T10000A Tape Drive - Version: Not Applicable and later   [Release: N/A and later ]
Information in this document applies to any platform.

Symptoms

There is no option to set a 4 GigaByte  T10000A drive into FICON mode.

Changes

Microcode removed this option for 4 GB drives.

Cause

T10000A drives FICON mode was only tested and designed to be used for 2 GB drives. It will cause intermittent interface errors when a 4 GB drive was used in FICON environments. A code change was put into 1.40. xxx code to remove the FICON mode option for 4 GB capable drives. 

Solution

Order a 2GB drive for any FICON T10000A spare drive if one is needed.