Solution Type Problem Resolution Sure Solution 1371346.1 : T10000A - Cannot Set FICON Emulation in a 4 GB Drive
In this Document
Applies to:Sun StorageTek T10000A Tape Drive - Version: Not ApplicableInformation in this document applies to any platform. SymptomsThere is no option to set a 4 GigaByte T10000A drive into FICON mode.ChangesMicrocode removed this option for 4 GB drives.CauseT10000A drives FICON mode was only tested and designed to be used for 2 GB drives. It will cause intermittent interface errors when a 4 GB drive was used in FICON environments. A code change was put into 1.40. xxx code to remove the FICON mode option for 4 GB capable drives.SolutionOrder a 2GB drive for any FICON T10000A spare drive if one is needed.Attachments This solution has no attachment |
||||||||||||
|