Asset ID: |
1-72-1369096.1 |
Update Date: | 2012-05-26 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1369096.1
:
VLE - VRTD Vary fails with UUIREQ error CC=30 RC=1
Related Items |
- Sun Virtual Library Extension (VLE)
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VLE
|
In this Document
Created from <SR 3-4419135621>
Applies to:
Sun Virtual Library Extension (VLE) - Version 1.0 and later
IBM z/OS on System z
Symptoms
Example error message when customer issued VARY RTD(xxxx) online from a VLE:
SLS0000I VARY RTD(V022) ONLINE
SLS6684I RTD VML2V022 on VTSS VTAPEM Returned UUIREQ error CC=30 RC=1
Display of RTD's, NOTE the RTD report failed/Offline
VT DISPLAY RTD
RTD | Mount | Alloc | Host | VTSS | Status |
V022 |
MP2058* |
- |
- |
VTAPE2 |
Fail/offline |
Cause
Hardware failure in VLE causing VRTD failure and to not come online.
Explanation of CC=30 RC=1, return code UUI Command Description
30/1 query-device The Value for the DEVICEID connection is not known.
Solution
1.) Issue command to find out what the RTD names are in the VLE box.
VT Display CONFIG or VT Query CONFIG, same command.
Here is output to look for. Note RTD NAME is what you are looking for.
Devno | RTD type | ACS | Retain | VTSSNAME RTD | CHANIF |
V022 |
VL |
VLE02 |
3 |
V2L2V012 |
0C IOI:0 |
|
|
|
|
|
|
2.) Issue command
VT VARY PATH(rtdname) OFFLINE Note the name is what is recorded in the VLE hardware.
Example RTD NAME V2L2V012 and for
DEVNO V022, which is what is in VTCS config
3.) Issue command
VT VARY PATH(rtdname) ONLINE. If path comes back online the proceed with next commands In this example PATH(V2LV012)
4.) Issue command
VT VARY RTD(devno) OFFLINE. It if comes offline, then issue next command. In this example RTD(V022)
VT VARY RTD(devno) ONLINE. If comes online, then you are good,
Display RTD's make sure RTD is now online.
Attachments
This solution has no attachment