Sun Fire X4100 Boot Up With Warning Message
Related Categories |
- PLA-Support>Sun Systems>x64>Server>SN-x64: SERVER 64bit
|
Created from <SR 3-4552451904>
Applies to:
Sun Fire X4100 M2 Server - Version Not Applicable and later
Information in this document applies to any platform.
Symptoms
X4100 Boot up with a warning message.
The message below was showed from BIOS screen:
WARNING:BIOS microcode patch for AMD Athlon(tm) 64/Opteron(tm) processor erratum 131 was not detected;updating your system`s BIOS to a version containing this microcode patchis HIGHLY recommended or erroneous system operation may occur.
Changes
Not Applicable
Cause
Please refer to the mentioned Bug ID's If the system BIOS is old . Please consider upgrading the same.
This is not a hardware issue and does not merit any component replacement. For Reference <SunBug: 6288246>
AMD Erratum 131 Warning Message Can Be Safely Ignored During OS Startup <SunBug: 6438926>
This workaround is present from Solaris 10 8/07 upward.
Solution
Solution is to upgrade BIOS <SunBug: 6288246>
Console Messages:
AMD Erratum 131 Warning Message Can Be Safely Ignored During OS Startup (6438926)
(Fixed in Solaris 10 8/07.)
Solaris AMD x64 support includes a boot-time check for the presence of a BIOS workaround for the AMD Opteron Erratum 131. If Solaris detects that the workaround for Erratum 131 is needed but it is not yet implemented, Solaris logs and displays the following warning message:
WARNING: BIOS microcode patch for AMD Athlon(tm) 64/Opteron(tm) processor erratum 131 was not detected; updating your system’s BIOS to a version containing this microcode patch is HIGHLY recommended or erroneous system operation may occur.
This warning message can be safely ignored. The BIOS implements a superset workaround that includes the workaround required for Erratum 131.