Solution Type Problem Resolution Sure Solution 1363466.1 : Infiniband GW Switch VNIC's in WAIT-IO state in Exalogic
In this Document
Created from <SR 3-4529751891> Applies to:Oracle Exalogic Elastic Cloud X2-2 Hardware - Version Not Applicable to Not Applicable [Release N/A]Oracle Exalogic Elastic Cloud Software - Version 1.0.0.0.0 and later Information in this document applies to any platform. SymptomsIn Exalogic environment issue of status of Infiniband GW Switch VNIC's showing WAIT-IO state instead of UP state was reported. Below were steps performed during the issue:
After running "showvnics" command VNIC's status was shown as WAIT-IO state instead of UP state. CauseExalogic GW switches were not connected into network using splitter cables which caused the ETH VNIC switches to stay in WAIT_IO state. SolutionTo resolve this issue connect Exalogic GW switches into datacenter network using splitter cables. ID STATE FLG IOA_GUID NODE IID MAC VLN PKEY GW Please refer to below documentation which has more information on vnics network configuration. Attachments This solution has no attachment |
||||||||||||||||
|