![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1362933.1 : Sun Storage 7000 Unified Storage System: Clients running Mac OS X Lion (10.7) can not connect To SMB shares
When connecting to SMB shares provided by a Sun 7000 Series Unified Storage System in conjunction with Active Directory from a Mac OS X 10.7 (Lion) clients, users might face permission errors. For other type of clients, such as older versions of Mac OS or Windows, there are no issues. In this Document
Created from <SR 3-4184997455> Applies to:Sun Storage 7310 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A]Sun Storage 7410 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 7210 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 7110 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun ZFS Storage 7120 - Version Not Applicable to Not Applicable [Release N/A] 7000 Appliance OS (Fishworks) SymptomsTo discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - 7000 Series ZFS Appliances
When trying to connect via SMB to shares provided by Sun Unified 7000 boxes with earlier versions than 2010.Q3.4.1, from a a MAC OS 7.1 client, users run into 'permission denied' messages on the client, when there are no problems with the same shares accessed via earlier version of Mac OS or Windows clients. CauseThis is a known issue caused by the different implementation of SMB services in Mac OS X 10.7 (Lion). SolutionUpgrade appliance software to 2010.Q3.4.1 (2010.08.17.4.1) or later, available from http://wikis.sun.com/display/FishWorks/Software+Updates
Back to <Document 1408716.1> Sun Storage 7000 Unified Storage System: How to Troubleshoot SMB (CIFS) Problems. References@ <BUG:7063347> - OS X LION (10.7.1) MAC USING SMB AND AD CANNOT CONNECT TO S7410<NOTE:1408716.1> - Sun Storage 7000 Unified Storage System: How to Troubleshoot SMB (CIFS) problems Attachments This solution has no attachment |
||||||||||||||||||
|