Solution Type Problem Resolution Sure Solution 1356932.1 : VSM/SVA - FSC7359 SIM Alert
In this Document
Applies to:Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0Sun StorageTek V2X SVA Disk System - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Information in this document applies to any platform. SymptomsThe VSM or SVA subsystem posted the SIM ref code 7359. Below is the definition for the ref code 7359:FSC7359_SNS_MIM_DISABLED_SIM 0x7359 The subsystem has encountered a condition that would normally generate a MIM (Machine Initiated Maintenance). Because the maintenance ports are not enabled the machine cannot initiate a service call. Please contact your service provider to request service. CauseA MIM has been generated on a machine that has both theEthernet and serial MIM offload paths disabled. This SIM is being created to report the event. The original MIM's FSC is stored in bytes 30-31 in the SIM's SNS data field. SolutionCheck sense bytes 30-31 in the sense data for the SIM to get the original FSC CodeConnect to the subsystem with either CSRC or SDP. Download and analyze the internal files to determine the cause of the MIM If there is a defective part, page the local FSE to replace it. Attachments This solution has no attachment |
||||||||||||
|