Solution Type Problem Resolution Sure Solution 1352613.1 : SL500 - There is an HP Variant Drive in a Oracle / STK Tape Library, Result Code 6451
In this Document
Applies to:Sun StorageTek SL500 Modular Library System - Version Not Applicable and laterInformation in this document applies to any platform. SymptomsSERVICE>> drive 0,2,4,9 getconfig NOTE : Below is an example from an SR with above mentioned problem : 6451 = "There is an HP variant drive in a non HP library" Customer has 2 new HP LTO5 drives installed to their SL500 by Partner. The library firmware was upgraded to 1409 from 1373 but the drives are still showing as incompatible and unknown. Doing a drive getconfig on the 2 new drives and it reported there is an HP variant drive in a non HP library. The drive tray has a HP part number. ChangesAdded HP LTO5 drives to library. CauseWrong type of drives installed. SolutionCustomer is using HP drives for an HP branded SL500 which is much different then the Oracle StorageTek SL500. These drives are not maintainable by Oracle. They will not work in Oracle library .... they were built for HP. The drives cannot be upgraded with Oracle firmware as there is a hook to prevent this from occurring by HP. The customer or Partner needs to acquire the proper drives.