Solution Type Problem Resolution Sure Solution 1351805.1 : When using a ZFS appliance with Exadata- Infiniband traffic is severely affected
After attaching a SUN 7XXX ZFS Appliance to an Exadata via Infiniband, all nodes on the Exadata system experience issues related to IB communications. In this Document
Created from <SR 3-4248778631> Applies to:Sun ZFS Storage 7320 - Version Not Applicable and laterExadata Database Machine X2-2 Qtr Rack - Version Not Applicable and later Oracle Exadata Storage Server Software - Version 11.2.2.3.0 and later Information in this document applies to any platform. ASM has issues in communicating with the cells and celldisks: ORA-15080: synchronous I/O operation to a disk failed At the server level- the NFS mounts on the ZFS Storage server also suffer. nfs:nfs_wait_on_write_congestion The entire Exadata cluster will either crash or be severely impaired SymptomsASM has issues in communicating with the cells and celldisks:
ORA-15080: synchronous I/O operation to a disk failed
At the storage server level- the NFS mounts on the ZFS Storage server also suffer.
In /var/log/messages:
nfs:nfs_wait_on_write_congestion
The entire Exadata cluster will either crash or be severely impaired
IB related messages will be found in many locations.
ChangesIf the ZFS Storage Appliance is running on software release <Q3.3 , then this issue can occur. CauseThe Firmware/Storage software on the ZFS Storage Appliance can cause IB network collisions. SolutionUpgrade the ZFS Storage Appliance to software version Q3.3 or later. Attachments This solution has no attachment |
||||||||||||||||||
|