Solution Type  Problem Resolution Sure

Solution  1350257.1 :   Sun Storage 7000 Unified Storage System: BUI shows " Hot Spare For 'Undefined' "  


Related Items
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun Storage 7110 Unified Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>NAS>SN-DK: 7xxx NAS
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Disk>Unified Storage
  •  


During a drive resilver, the BUI fails to declare which drive the hot spare is in use for.

In this Document
  Symptoms
  Changes
  Cause
  Solution


Created from <SR 3-4199004751>

Applies to:

Sun Storage 7110 Unified Storage System - Version: Not Applicable and later   [Release: N/A and later ]
Sun Storage 7210 Unified Storage System - Version: Not Applicable and later    [Release: N/A and later]
Sun Storage 7310 Unified Storage System - Version: Not Applicable and later    [Release: N/A and later]
Sun Storage 7410 Unified Storage System - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Symptoms

When  a hot spare is in use after a drive failure, the BUI fails to identify which drive the hot spare is in use for and marks it 'undefined' instead

Changes

A drive failure will trigger this

Cause

<SUNBUG: 6897292>

Solution

The bug is fixed in the 2011.1 release