![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1349776.1 : SL500 - All Modules Not Being Seen After Code Upgraded From 1092 to 1409
In this Document
Applies to:Sun StorageTek SL500 Modular Library System - Version: Not ApplicableInformation in this document applies to any platform. SymptomsNot seeing all modules after upgrading code.Missing module from lib getconfig information. Before the upgrade I displayed the following via the CLI libstate print Current Status Library State: READY CAP Status: CAP Locked: FALSE CAP Access State: CLOSED PTP Status: NOT INSTALLED OK SERVICE>> lib getconfig Library Configuration Unit Type SL500 Total number of modules 3 <-------------Shows 3 Modules Module 1 type 25 Module 2 type 17 Module 3 type 16 Total number of PTPs 0 Total number of CAPs 3 Total number of CAP cells 25 Total number of storage cells 143 Total number of reserved cells 1 Total number of tape drives 10 0,1,1,9 0,1,2,9 0,2,1,9 0,2,2,9 0,2,3,9 0,2,4,9 0,3,1,9 0,3,2,9 0,3,3,9 0,3,4,9 Host Interface Configuration: Interface Type: FIBRE Node WWN: 500104f0008238b8 Port A WWN: 500104f0008238b9 Port A is Enabled Port A Hard Addressing: Disabled Port A Address: AUTO Port A speed: 2GBit OK SERVICE>> network print Network Configuration Machine Network Name: prsys05 IP Address: 10.1.2.21 Subnet Mask: 255.255.252.0 Gateway:(optional) 10.1.1.1 SERVICE>> After the upgrade the CLI shows: SERVICE>lib getconfig Library Configuration Unit Type SL500 Total number of modules 2 <------- Missing the 3rd Module Module 1 type 25 Module 2 type 17 Total number of PTPs 0 Total number of CAPs 2 <------Missing 3rd CAP Total number of CAP cells 15 Total number of storage cells 143 <-----Cell count remained the same Total number of reserved cells 1 Total number of tape drives 10 0,1,1,9 0,1,2,9 0,2,1,9 0,2,2,9 0,2,3,9 0,2,4,9 0,3,1,9 0,3,2,9 0,3,3,9 0,3,4,9 Total number of empty storage cells 12 Total number of restricted cells 143 Host Interface Configuration: Interface Type: FIBRE Node WWN: 500104f0008238b8 Port A WWN: 500104f0008238b9 Port A is Enabled Port A Hard Addressing: Disabled Port A ID : Auto Negotiate Port A speed: 2GBit OK SERVICE>> libstate print Current Status Library State: READY CAP Status: CAP Media Removal: ALLOWED CAP Access State: CLOSED CAP Door Sensors: Module 1: CLOSED Module 2: CLOSED Module 3: CLOSED PTP Status: NOT INSTALLED OK SERVICE>> ChangesCode upgraded from 1092 to 1409.CauseUsing down level SL Console code, 4.50.SolutionUpgrade SL Console firmware from 4.50 to 4.75 or higher.This allowed the key from E-Delivery to be installed correctly and all modules along with CAPs were displayed. Attachments This solution has no attachment |
||||||||||||
|