Solution Type  Problem Resolution Sure

Solution  1347994.1 :   Exadata Command "Calibrate Force" Fails With CELL-02018  


Related Items
  • Oracle Exadata Storage Server Software
  •  
  • Exadata Database Machine X2-2 Full Rack
  •  
Related Categories
  • PLA-Support>Database Technology>Engineered Systems>Oracle Exadata>DB: Exadata_EST
  •  
  • .Old GCS Categories>ST>Server>Engineered Systems>Exadata>Administration and Configuration
  •  




In this Document
  Symptoms
  Cause
  Solution
  References


Created from <SR 3-4256944361>

Applies to:

Exadata Database Machine X2-2 Full Rack - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Oracle Exadata Storage Server Software - Version: 11.2.1.2.0 to 11.2.2.2.2   [Release: 11.2 to 11.2]
Information in this document applies to any platform.

Symptoms


Calibrate Force command on Exadata environment fails with following error.

ERROR
==========
CELL-02018: Internal error detected: Can't find resource for bundle oracle.ossmgmt.ms.rsc.CliMsg, key CALIB_SEQ_TESTS

Cause

The cause of this problem has been identified and verified in an unpublished Bug 10411690

The details of this bug.


1) The command being executed was calibrate force

2) Error matches with following when running calibrate.

ERROR

-----------

CELL-02018: Internal error detected: Can't find resource for bundle oracle.ossmgmt.ms.rsc.CliMsg, key CALIB_SEQ_TESTS

Solution

1)  This bug is generally seen when substandard luns are detected so please get the hardware thoroughly checked. However it is possible in some scenarios to get this error even though hardware is fine.

2) Upgrade Exadata Cell Software to 11.2.2.3.0 or higher in which this bug is fixed.

References

<BUG:10411690> - MISSING CELLLCI MESSAGE WHEN BAD LUNS NEED TO BE REPORTED: CELL-02018