Solution Type Problem Resolution Sure Solution 1347994.1 : Exadata Command "Calibrate Force" Fails With CELL-02018
In this Document Created from <SR 3-4256944361>
Applies to:Exadata Database Machine X2-2 Full Rack - Version: Not Applicable to Not Applicable - Release: N/A to N/AOracle Exadata Storage Server Software - Version: 11.2.1.2.0 to 11.2.2.2.2 [Release: 11.2 to 11.2] Information in this document applies to any platform. Symptoms
ERROR CauseThe cause of this problem has been identified and verified in an unpublished Bug 10411690 The details of this bug.
ERROR ----------- CELL-02018: Internal error detected: Can't find resource for bundle oracle.ossmgmt.ms.rsc.CliMsg, key CALIB_SEQ_TESTS Solution1) This bug is generally seen when substandard luns are detected so please get the hardware thoroughly checked. However it is possible in some scenarios to get this error even though hardware is fine. 2) Upgrade Exadata Cell Software to 11.2.2.3.0 or higher in which this bug is fixed. References<BUG:10411690> - MISSING CELLLCI MESSAGE WHEN BAD LUNS NEED TO BE REPORTED: CELL-02018Attachments This solution has no attachment |
||||||||||||
|