Solution Type Problem Resolution Sure Solution 1343179.1 : V2XF - Host IEA480E message with REFCODE of FSC3FDF
V2X subsystem posted a SIM message with FSC 3FDF In this Document
Applies to:Sun StorageTek V2X SVA Disk System - Version: Not Applicable to Not Applicable - Release: N/A to N/AInformation in this document applies to any platform. SymptomsV2X posted SIM message with the following information in it:IEA480E aaaa,SCU,MODERATE ALERT,MT=2105,SER=ssss-sssss,REFCODE=3FDF-zzzz-zzzz More detail: aaaa is the address associated with the SIM message SER is serial number which is posting the SIM message REFCODE = Provides data of the event, including the FSC code CausePPRC LINK LOST CONNECTION ON IFC CARD SLOT 13 BOTTOM CONNECTIONSolutionRecovery steps:NOTE: The V2X is stating the link is down between this V2X and the secondary unit, not that it has dropped the link. 90% of these events are caused by something external to the subsystem. 1. Attempt to reestablish the link with CESTPATH command for this link. If successful, monitor for re-occurrence. 2. If the link can not be established, contact the vendor of the network between the two units. Contact Oracle to review the status of the V2X that posted the SIM and the secondary V2X. Attachments This solution has no attachment |
||||||||||||
|