![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1342786.1 : V2XF - Host IEA480E message with REFCODE of FSC3FDx
V2x Subsystem posted a SIM message with FSC3FD0 In this Document
Applies to:Sun StorageTek V2X SVA Disk System - Version: Not Applicable to Not Applicable - Release: N/A to N/AIBM z/OS on System z SymptomsV2X posted SIM message with the following information in it to the host:IEA480E aaaa,SCU,MODERATE ALERT,MT=2105,SER=ssss-sssss,REFCODE=3FDx-zzzz-zzzz More detail: aaaa is the unit address reporting the SIM message SER is the serial number referenced by the SIM message REFCODE = Provides data of the event, including the FSC Note: The cause and solution only apply if the serial number belongs to the V2X hardware and if Fault Symptom Code 3FDx is the REFCODE. REFCODE=3DFx applies to 3FD0 thru 3FDF. This FSC is applicable only to PPRC, Peer-to-Peer Remote Copy, an available feature of the V2X hardware. CauseFAULT SYMPTOM CODESFSC3FD0 FSC3FD1 FSC3FD2 FSC3FD3 FSC3FD4 FSC3FD5 FSC3FD6 FSC3FD7 FSC3FD8 FSC3FD9 FSC3FDA FSC3FDB FSC3FDC FSC3FDD FSC3FDE FSC3FDF REFCODE DESCRIPTION 3FD0 - PPRC link lost connection on IFC CARD SLOT 00 top interface 3FD1 - PPRC link lost connection on IFC CARD SLOT 00 bottom interface 3FD2 - PPRC link lost connection on IFC CARD SLOT 01 top interface 3FD3 - PPRC link lost connection on IFC CARD SLOT 01 bottom interface 3FD4 - PPRC link lost connection on IFC CARD SLOT 02 top interface 3FD5 - PPRC link lost connection on IFC CARD SLOT 02 bottom interface 3FD6 - PPRC link lost connection on IFC CARD SLOT 03 top interface 3FD7 - PPRC link lost connection on IFC CARD SLOT 03 bottom interface 3FD8 - PPRC link lost connection on IFC CARD SLOT 10 top interface 3FD9 - PPRC link lost connection on IFC CARD SLOT 10 bottom interface 3FDA - PPRC link lost connection on IFC CARD SLOT 11 top interface 3FDB - PPRC link lost connection on IFC CARD SLOT 11 bottom interface 3FDC - PPRC link lost connection on IFC CARD SLOT 12 top interface 3FDD - PPRC link lost connection on IFC CARD SLOT 12 bottom interface 3FDE - PPRC link lost connection on IFC CARD SLOT 13 top interface 3FDF - PPRC link lost connection on IFC CARD SLOT 13 bottom interface SolutionRecovery steps:NOTE: The V2X is stating the link is down, not that it has dropped the link. 90% of these events are caused by something external to the subsystem. 1. Attempt to reestablish the link with CESTPATH command including all links. If successful, monitor for re-occurrence. 2. If the link can not be established, contact the vendor of the network between the two units. Contact Oracle to review the status of both the V2X that posted the SIM and the secondary V2X. Attachments This solution has no attachment |
||||||||||||
|