Solution Type Problem Resolution Sure Solution 1339745.1 : SL8500/SL3000 - Policy Routes Disable after Power Cycle of Library
In this Document
Oracle Confidential (PARTNER). Do not distribute to customers
Applies to:Sun StorageTek SL8500 Modular Library System - Version: Not ApplicableSun StorageTek SL3000 Modular Library System - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform. SymptomsPolicy Routes Disable after Power Cycle.After power cycling the subsystem the Policy Rules change from ENABLED to DISABLED. ChangesPower cycling the library.CauseIssue found in 2.81 and 6.x code versions.SolutionRecovery is to use "network ip policy enable dev 2A" and "2B" commands to re-enable.Specific command syntax to enable and check the policy statements and note policy routes are typically used with the dual tcp/ip feature. network ip policy enable dev 2A network ip policy enable dev 2B network ip policy route show dev 2A network ip policy route show dev 2B This problem fixed in SL3000 FRS_3.00 code and in SL8500 FRS_7.01 code. Provided by Bruce McDonald Attachments This solution has no attachment |
||||||||||||
|