Solution Type Problem Resolution Sure Solution 1339386.1 : V480/V490 Memory Failure (POST errors and diagnostics)
In this Document Created from <SR 3-4060432401>
Applies to:Sun Fire V490 Server - Version: Not ApplicableInformation in this document applies to any platform. Symptoms=== ODM Issue Clarification ===Memory DIMM module has failed which resuted in server being hung. === ODM Issue Verification === 2:0>WARNING: TEST = Block Memory 2:0>H/W under test = CPU0, All CPU0 Memory 2:0>MSG = Data or Instruction Access Error, Trap Type 00000000.00000063 Trap PC ffffffff.f0124bb0 Trap Level 00000000.00000001 AFSR 00100002.00000034 AFAR 00000020.4334da90 2:0>END_WARNING 2:0>ERROR: TEST = Block Memory 2:0>H/W under test = CPU2 Bank 0 Dimm 1, J7901 side 1 2:0>Repair Instructions: Replace items in order listed by 'H/W under test' above. 2:0>MSG = DIMM failure Bank 0 DIMM 1 Pin 145 2:0>END_ERROR Cause=== ODM Cause Determination === DIMM failure === ODM Cause Justification === 2:0>ERROR: TEST = Block Memory 2:0>H/W under test = CPU2 Bank 0 Dimm 1, J7901 side 1 Solution=== ODM Solution / Action Plan === DIMM must be replaced following the instructions sent to the FE. After replacement an extended POST must be performed to verify the HW status. Attachments This solution has no attachment |
||||||||||||
|