Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1338173.1
Update Date:2011-07-18
Keywords:

Solution Type  Problem Resolution Sure

Solution  1338173.1 :   VTL - Failed To Expand Virtual Tape Id Virtual Tape  


Related Items
  • Sun StorageTek VTL Plus Storage Appliance
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VTL
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  




In this Document
  Symptoms
  Cause
  Solution


Created from <SR 3-3756393856>

Applies to:

Sun StorageTek VTL Plus Storage Appliance - Version: 1.0 - Build 1323 to 2.0 - Build 1656 - Release: 1.0 to 2.0
Information in this document applies to any platform.

Symptoms

Error message shows up in the vtl error logs saying that tape expansion failed, followed by ioctl time out error:
 

Jun 1 06:58:18 xxxxxxvtl08 sanidmgr[1007]: [ID 702911 daemon.notice] IPSTOR||0||E||0x00009c85||cannot expand tape||11323||-1
Jun 1 06:59:12 xxxxxxvtl08 kfsnbase: [ID 831650 kern.info] FSNBASE ioctl_wait_timed_out(), pid -1990821088, function 10, owner_pid -1994978176, owner_function 44 

And then after few minutes message comes up in the log file saying that the tape gets expanded successfully:

Jun 1 06:59:27 xxxxxxvtl08 ipstorcomm: [ID 702911 daemon.notice] IPSTOR||1306925967||I||0x00002cef||expanded virtual tape||VIRTUAL TAPE id 11323||7168

Jun 1 06:59:28 xxxxxxvtl08 genunix: [ID 459543 kern.notice] <6>[fffffe80020d1c80] TLE_INFO: Tape 11323 Expanded successfully, new size 20401094656 bytes

Cause

The tape expand failed is due to the ioctl time out, this is not related to the shrinking time out previously. The ioctl time out is not a real issue. As long as the tape expanded successfully afterwards in couple minutes, it should not cause issue on the tape. The ioctl time out happens sometime when the downstream storage is busy on updating the tape information.


Solution

This error can be ignored, as long as the subsequent tape expansion for that same tape was successful (see Symptom section above for sample messages for verifying).
Attachments
This solution has no attachment