Solution Type  Problem Resolution Sure

Solution  1336007.1 :   PS Failure on Sun Fire V480/V490  


Related Items
  • Sun Fire V480 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-Vx80
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
  •  




In this Document
  Symptoms
  Cause
  Solution


Created from <SR 3-3993606601>

Applies to:

Sun Fire V480 Server - Version: Not Applicable and later   [Release: N/A and later ]
Information in this document applies to any platform.

Symptoms


=== ODM Issue Clarification ===
PS1 Failed


=== ODM Issue Verification ===
Power Supplies:
---------------

Supply Status Fault Fan Fail Temp Fail
------ ------------ -------- --------- ---------
PS0 [NO_FAULT ] OFF OFF OFF
PS1 [DEVICE_FAIL ] ON OFF OFF

Cause


=== ODM Cause Determination ===
PS failure


=== ODM Cause Justification ===
Led alarmed, HW status shows PS1 failed

Solution


=== ODM Solution / Action Plan ===

1.- Perform the PS replacement following the instructions sent to the FE.
2.- Test the system and verify if the issue was solved.

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback