![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1334777.1 : Sun Storage 7000 Unified Storage System: System hang - aksh scripts can exhaust memory
Running aksh scripts can exhaust memory and may cause system to hang. In this Document
Created from <SR 3-2918454851> Applies to:Sun ZFS Storage 7420 - Version Not Applicable to Not Applicable [Release N/A]Sun ZFS Storage 7320 - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 7110 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 7310 Unified Storage System - Version Not Applicable to Not Applicable [Release N/A] Sun ZFS Storage 7120 - Version Not Applicable to Not Applicable [Release N/A] 7000 Appliance OS (Fishworks) SymptomsRunning (many) aksh scripts can exhaust memory and may cause system to hang. To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - 7000 Series ZFS Appliances
CauseRunning (many) aksh scripts can exhaust the Appliance management daemon kernel memory. SolutionFor a 'temporary workaround', reboot the system - or engage Oracle Support, by opening a Service Request, so that Oracle Support Services can provide confirmation of this issue and then carry out the appropriate activities to resolve the issue. NOTE - If upgrading to 2011 software and running a 7x10 system with SAS-1 Disk Trays then upgrade to 2011.1.2.1 or later. See FISHworks wiki Software Updates page to download the latest version.
Back to <Document 1401282.1> Sun Storage 7000 Unified Storage System: How to Troubleshoot Unresponsive Administrative Interface (BUI/CLI Hang). References@ <BUG:6994721> - AKSH SCRIPTS CAN EXHAUST MEMORYSoftware Updates page: https://wikis.oracle.com/display/FishWorks/Software+Updates <NOTE:1401282.1> - Sun Storage 7000 Unified Storage System: How to Troubleshoot Unresponsive Administrative Interface (BUI/CLI hang) Attachments This solution has no attachment |
||||||||||||||||||
|