Solution Type Problem Resolution Sure Solution 1333021.1 : SL3000 - Manual Clean of Drive Not Incrementing Use Count
In this Document
Applies to:Sun StorageTek SL3000 Modular Library System - Version: Not ApplicableInformation in this document applies to any platform. SymptomsManual Clean not Incrementing Use CountCauseUnlike the SL500, the SL3000 does not have a Manual Cleaning option in the SLConsole when using AutoClean.SolutionManual cleans can only be accomplished by using a Diagnostic Move command from the SLConsole. When using a cleaning tape in this manual manner, the "use count" of the cleaning tape will not increment. This is known behavior and there is no current plan to modify it.NOTE: Manual cleaning will have no effect on many drives if the transport is not in a "clean requested" state. In addition, routine manual cleans can have detrimental effects such as decreased head life. Engineering recommends that cleaning should be done only when a transports requests a clean. Attachments This solution has no attachment |
||||||||||||
|