Asset ID: |
1-72-1332517.1 |
Update Date: | 2012-06-28 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1332517.1
:
Firmware upgrade on Sun Fire V245 fails with "Can't open /flash-update-SunFire245"
Related Categories |
- PLA-Support>Sun Systems>SPARC>Workgroup Servers>SN-SPARC: SF-V2x0
|
In this Document
Created from <SR 3-3858172649>
Applies to:
Sun Fire V245 Server - Version Not Applicable and later
Information in this document applies to any platform.
Symptoms
System is running S10 U5 or earlier and following the Install.info file from the patch.
When booting from OBP to carry out the upgrade it fails as below:
Rebooting with command: boot disk /flash-update-SunFire245
Boot device: /pci@1e,600000/pci@0/pci@a/pci@0/pci@8/scsi@1/disk@0,0:a File and args: /flash-update-SunFire245
-
Can't open /flash-update-SunFire245
Warning: Fcode sequence resulted in a net stack depth change of 1
Evaluating:
Evaluating:
The file just loaded does not appear to be executable.
{1} ok
Cause
The Solaris system was running S10 U4 but had kernel Patch 137137-09 installed, this patch implements boot archive support and this causes the system at boot time to look for alternate kernel's to boot from the boot archive and because the file flash-update-SunFire245 cannot be found in there this causes the boot failure seen.
Solution
From the Install.info instructions file in the patch ensure you follow section 4) b) instructions in the patch to put the flash-update file into the boot archive:-
# echo flash-update* >> /boot/solaris/filelist.ramdisk
# bootadm update-archive
Attachments
This solution has no attachment