Solution Type Problem Resolution Sure Solution 1331928.1 : Disk Drive Fan Failure
In this Document Created from <SR 3-3860882421>
Applies to:Sun Enterprise 3500 Server - Version: Not ApplicableInformation in this document applies to any platform. SymptomsDisk drive fan failure messages seen in /var/adm/messages* and prtdiag=== Issue Verification === From prtdiag -v: ========================= Environmental Status ========================= Keyswitch position is in Normal Mode System Power Status: Redundant System LED Status: GREEN YELLOW GREEN WARNING ON ON BLINKING Fans: ----- Unit Status ---- ------ Disk FAIL Detected System Faults ====================== Disk Drive Fan failure Detected Fri Jun 3 21:37:59 2011 PROM detected failure Detected Fri Jun 3 21:37:59 2011 From /var/adm/messages* Jun 3 12:46:12 xxxx unix: WARNING: Disk Drive fan failure detected CauseThe E3500 Fan tray that sits below the Disk Drive assembly has failed or is failing.These Fans provide cooling to the FCAL disks, therefore, the error messages indicate Disk Drive Fan Failure. The Fan Tray is a complete FRU with 3-Fan Assembly. Solution=== Action Plan === FE on-site must replace the 3-Fan Tray Assembly with part number 540-3566 [F] Attachments This solution has no attachment |
||||||||||||
|