Asset ID: |
1-72-1328487.1 |
Update Date: | 2012-05-14 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1328487.1
:
Sun Netra X4200 M2 Server / Lsi Sas Raid gives an error after Poweroff and Poweron
Related Items |
- Sun Netra X4200 M2 Server
|
Related Categories |
- PLA-Support>Sun Systems>x64>Server>SN-x64: TELCO-NETRA
|
In this Document
Created from <SR 3-3722123530>
Applies to:
Sun Netra X4200 M2 Server - Version Not Applicable and later
Information in this document applies to any platform.
Symptoms
During booting the server the LSI Controller give the following error message:
Integrated RAID exception detected
Volume (00:002) is currently in state Failed
But entering the LSI Configuration tool not errors are seen
Changes
The system board Battery Voltage are lower then 3 Volt (current 2,88 Volt), but not in a critical condition.
Regarding the issue description the issue occur during a power off, where the Battery should hold the settings.
Cause
This problem can happen, if the Voltage from the system board battery is lower then 3 Volt
Solution
Check the Voltage value of the system board battery using the WEB UI from the ILOM
Put in the ip address from the ILOM into a browser url and login as root into the ILOM UI.
Click at System Monitoring - Sensor Reading
click at the links /sys/mb/v_bat
and see if the Voltage value is not less "lower_nonrecov_threshold"
If the Voltage from the system board battery is lower then 3 Volt, replace system board battery
Attachments
This solution has no attachment