Solution Type  Problem Resolution Sure

Solution  1320556.1 :   VSM - Channel Card Reporting FSC32C0 Parity Errors  


Related Items
  • Sun StorageTek VSM System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VTL
  •  
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-3572010301>

Applies to:

Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]
IBM z/OS on System z

Symptoms


Customer reports z/OS host SYSLOG SIM messages with FSC32C0 embedded in the message.

Example:
SLS6659I VTSS VTSS1 SIM:5090100000008FE0329080009E001A104200105C000032C00510420110068012

SLS6974I FAULT REPORTED BY VTSS:VTSS1 MODEL:VSMx SERIAL:xxxxxxxx FSC:32C0 FRU:xxx

Note:  SIM Sense Bytes 22 & 23 are 32C0.

Fault symptom codes other than 32C0 may occur with messages SLS6659I and SLS6974I and are beyond the scope of this article.

Cause


Defective channel card

#define FSC32C0_OM_ESCON_CIP_MEM_PAR_CHK 0x32C0

CSE: @SAME
ENG: An ICE CIP memory parity check 2 error was detected.
This error occurs when the CIP reads one of its memory
locations and bad parity is present on the data word.

Solution

Open a service request for further analysis.
Include the complete text of the SLS messages.

VSM remote support will perform the following tasks:

  1. Connect to VSM and acquire a set of base files.
  2. Place files on zenobia.
  3. Run the crunch_it all.
  4. Review the files to check for FSC 32C0 and identify card type, location, part number.
  5. Create Field Service Task for local to replace defective channel card.

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.