Solution Type  Problem Resolution Sure

Solution  1316184.1 :   VSM - Warmboot FSC7596 with 3BC8 in sense bytes 30,31 of SIM message  


Related Items
  • Sun StorageTek VSM System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VTL
  •  
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  




In this Document
  Symptoms
  Cause
  Solution
  References


Created from <SR 3-3443801641>

Applies to:

Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0
IBM z/OS on System z

Symptoms

SLS6659I SIM occurs on the z/OS host logs.  This SIM from the VSM includes 7596 in sense bytes 22 and 23, indicating a warmboot occurred and bytes 30 and 31 contain 3BC8. 

Fault Symptom Codes
-----------------------
FSC7596_FI_CHECK_0_WARM_BOOT_COMP_OK
FSC3BC8_DISCONNECTED_TIMEOUT_DUE_TO_UNKNOWN_DEV_STAT

Cause

VSM Microcode
 CR 7015268, Product Family: Sun


Solution

First, verify successful recovery from the warmboot and the recording of FSC3BC8 in the VSM logs. Contact VSM technical support to help verify if necessary.

Second, on VSM4 or VSM5, schedule upgrading the microcode to D02.12.08.00 or higher level.  On VSM5C, upgrade to H02.12.08.00 or higher level of microcode.



References

<BUG:7015268> - ROYAL BANK OF CANADA- CK0 FSC 3BC8 AND 2 FSC 3BC7 RUNNING D02.11.18 (SCN 50734)
<NOTE:1317325.1> - VSM - SLS6659I SIM error with FSC7596
<NOTE:1014781.1> - How to Determine the FSC from the Sense Bytes in Message SLS6659I